Macintosh Compatible USB Microscopes
Shopping for a consumer or professional digital microscope for Mac OSX? A surprising number Apple computer users in specific medical, educational and industrial work environments are in the market for MacOS compatible USB digital microscope products.ToupView is a camera control application for Mac OS. It provides functions to fully control the camera and present the videostream processed by Ultra FineTM color engine at high speed, which includes dedicated pipeline to process the raw data into a realistic scene. OMAX sells microscopes at low prices for a wide range of applications, including school, clinic, veterinarian, geology, metallurgy, stereo inspection, and much.
MAC: Last Update: Download Llumins ToupView Software (39MB) Installation: Save file to the applications folder, then from the Launch pad find Toupview icon and run. Configure: For the best image clarity and setup, disable auto exposure once you opened the program, then setup auto white balance first by selecting a blank space on the. ToupTek ToupView Setup for Windows. OptixCam Twain Setup for Windows. OptixCam Dshow Setup for Windows. OptixCam ToupLite Setup for OS X. OptixCam Air & OptixCam KoPa C-500W Wifi. Micro Capture for Windows 264 MB (includes driver) Micro Capture for Mac. OptixCam Classic Summit and Pinnacle Series Software for X Series Cameras. . UVC cameras work with newer 'plus' versions of Mac software, but may not work on older software versions for Mac. Driver software is used by a computer's operating system to define how the camera works, and how applications can use it.
Digital Microscopes For Mac Comptuers
A broad range of Mac compatible microscopes are available. They range from low-cost student and consumer-grade products to complete professional quality digital lab microscope sets. Those with UVC - USB Video Class compatible camera sensors make them plug and play on OSX 10.5 and higher with the built-in webcam drivers in Apple's OSX operating system.USB Microscope For Mac Recommendations
Mac Compatible Microscope | Digital Mac Lab Microscope | Binocular Digital Scope |
---|---|---|
USB Student Microscope Affordable Monocular Scope | Digital Trinocular Microscope 40x-2000x Magnification | Omax Binocular Microscope Illuminated Mechanical Stage |
Toupview For Macbook Air
Above is just a sampling of the types of Apple compatible USB digital microscope equipment available from both AmScope and OMax, two of the leading manufacturers in the industry. Amscope in particular is a leading brand featuring good Apple support for it's digital offerings in the diverse medical, dental, pharma, biology, educational and industrial environments it serves.
OSX Compatible USB Inspection Scope Webcams
A wide selection of Mac compatible scopes and cameras for engine and mechanical parts inspection are available. There are digital scope cameras for physical assessment, hobby, business and industrial needs available. The best USB scopes feature built-in LED lighting near the sensor. Many feature adjustable LED lighting controls for setting the optimal amount of light available to the camera to illuminate dark, hard to reach spaces like dental mouth exams, internal body orifices or complex mechanical parts.![Toupview For Mac Toupview For Mac](/uploads/1/1/8/3/118392295/233164528.jpg)
Mac Compatible Microscope | Mac USB Camera Borescope | Mac Scope With Stand |
---|---|---|
Mac Inspection Scope 50x-200x Magnification | USB Endoscope - Otoscope OSX 10.5 Or Higher | OSX Compatible Scope Adjustable LED Lighting |
USB Digital Microscope Software For Mac OSX
Some manufacturers provide Apple specific software for their scopes. But often Digital USB microscope hardware DOES NOT come with any MacOS specific software to control zoom functions or capture still snapshots, time-sequence or full motion video clips with.However, because these are USB Video Class - UVC compatible microscopes, they should provide BASIC functionality on any modern Macintosh running MacOS Mojave or Sierra, OSX ElCapitan, Yosemite, Mavericks, Lion or Leopard when attached to a USB 2.0 or USB 3.0 SuperSpeed port.
Basic operation can be as simple as launching Apple's PhotoBooth, QuickTime or other OSX video capture app. Then make sure the external scope is selected in the software's CAMERA SOURCE Preferences... menu. You may have other MacOS still photo and video grabbing software you prefer to use for still image, time-lapse or video clip capture.
Here's a link to Digital Viewer App - OSX 10.5+ compatible general purpose Mac microscope software from Plugable Technologies. It works with any UVC compatible webcam or scope and supports VGA up to 1080p and higher HD resolution depending on the camera's capabilities. It offers timed-shots, single-shots and movie capture modes.
There's Mac software for AmScope's various digital microscope product lines: AmScopeXLite, ProScope or ISCapture
Toupview For Macbook Pro
that you can download from the company's software page. There is also an 3rd-party app called ToupViewToupview For Macbook
is available for download here. It seems to be hardware manufacturer specific and likey polls the USB bus to ascertain if an AmScope brand USB camera device is attached to function.Other Mac Digital USB Microscope Software Apps
Digital Pan and Zoom control over your scope's camera image might be something you need. You can download a free trial of iGlasses webcam control software app from eCamm or the affordable Mactaris Webcam app and see if it helps you achieve the zoom and magnification control you need to get the most out of your digital microscope or inspection scope. You may also need it for webcam image adjustment to control camera brightness, contrast, color saturation and other image enhancements.All told, there's decent support for digital microscopy on Apple platforms. Some may even be usable on an iPad tablet or iPhone when paired with a USB camera connection kit dongle in your handheld device's 30-pin or Lightning dock connector.
AmScope/Toupview Windows PC Software FAQ
(For MU and MD Series Camera Only)
(For MU and MD Series Camera Only)
FAQ PDF Can be Downloaded here.
Q: The drivers have been installed but when I try to view an image in the software, we get an error message that says “Cannot preview, try again (error code hr=0x80004005)”
A: Several factors will result in this. The following test methods will help find the exact reason:
- Slow down the Frame Speed Level or select lower resolution. If the camera can work under a slower speed level or a lower resolution, the computer may have a smaller USB bandwidth than the USB 2.0 standard;
- Unplug and re-plug the camera or use another USB cable. Sometimes the USB cable and the USB port on the camera may have a poor contact, so that the computer and the camera are unable to communicate;
- Use another USB port on the computer. Different USB ports on the computer have different performance. Normally the USB ports at the back of a computer have better performance than the front ones;
- Use another computer. Different USB root hubs of different computers may differ greatly. Normally USB root hubs of a desktop computer have better performance than those of laptops.
Q: The camera is started but the Video window is always black.
A: This could be caused by 3 reasons:
![Toupview mac download Toupview mac download](/uploads/1/1/8/3/118392295/796857986.png)
- Make sure that you’ve removed all caps from the camera and reduction lens. Most users always forget to remove the cap that’s on top of the reduction lens. Please reference this picture:
- If you’re using a Trinocular microscope such as our SM or ZM Series Microscope, and you have your camera in the trinocular port, make sure that you adjust the pin on the left hand side of the system that opens the shutter to the trinocular port:
- If those two other reasons didn’t work, you can try this method:
- Please choose “Setup–>View Properties” in the menu so that you can check the “Actual Frame Rate” as shown below:If the actual frame is 0, it could be because the transfer bandwidth of the computer’s USB root hub is not sufficient to transfer high sped video stream at large resolution. Slow down the Frame Speed Level and/or decrease the resolution. The pictures below will show you how to solve that problem:
Q: How do I increase the frame rate/speed level of the camera when using the Software?
A: We made a video on how to increase frame rate here:
Q: Why doesn’t my system start up (boot) if the camera is plugged in?
Toupview For Mac Os
A: A few computer’s BIOS settings are not compatible with the camera (such as DELL Dimension 2400). Try to turn off some USB related functions in the comptuer’s BIOS settings such as USB Emulation. This may solve the problem.
Q: How do I capture single frames and video clips when using the camera?
A: Please refer to the software user manual in Section 2.6 You can access the manual by clicking “Help–>Help Contents”
Q: How do I change the unit of measurement in Toupview?
A: You have to define the Software Power and Calibrate your camera with your microscope before the units of measure will work. Please reference sections “15.3 Magnifications and 15.4 Calibrate” in the manual. You can also watch a video on how to calibrate your microscope and camera here:
Q: Why is the camera not recognized by the computer?
A: There may be something wrong with either the USB root hub, the USB cable, or you may not have installed the drivers for the camera. Make sure that you have the latest drivers for the camera installed. If that’s already installed, there could be an issue with the USB cable. Try using a different USB cable. Also try the camera with another computer.
Q: What does bin/skip mean?
A: Bin and skip are two sub-sample methods and not all models support this feature. Bin averages the adjacent pixels from the full resolution to get smaller resolutions while skip just picks one of the adjacent pixels from the full resolution to get smaller resolutions. As a result, the video quality of bin is better but the average will take more time to generate a frame. The bin/skip feature is summarized as follows:
Q: Are you going to have a Gigabit Ethernet interface for future cameras?
Toupview Mac Download
A: No, Gigabit Ethernet interface cameras will not be produced because we already have USB 3.0 cameras which have a faster interface.